It will trip the breaker automatically if the sensor is triggered. It is designed to connect to a secondary sensor. What is a shunt trip breaker? The shunt trip is an optional accessory for a circuit breaker for added protection to your system.

Ground isolator power strip manual#

It’s best to read up on the manual or consult an electrical professional before making any changes. DIY installation may void the warranty of your breakers.

ground isolator power strip

Ground isolator power strip install#

Some makers only allow a factory install of the shunt trip and other accessories. You may need a shunt trip breaker diagram as a reference to ensure correct installation.Īlso, check the brand and model of your breaker before proceeding with the installation. However, the critical part of every installation is that you need to connect the shunt to your sensor.

ground isolator power strip

It would depend on the brand and model of the breaker. Note: Every circuit breaker comes with different instructions. You can watch this video by Aaron CBIONE for some tutorials. Once you’re sure that your system can take a shunt trip accessory, installation is pretty much straightforward. Also, not all breaker models are compatible with this accessory. Mostly, installing a shunt trip relay requires that the breaker and the shunt be from the same maker.

Ground isolator power strip how to#

How to Install a Shunt Trip Accessory to the Breaker These codes refer to the controls and safety standards provided by ASME’s. Commercial kitchens use this device in compliance with ANSI/ASME CSD-1, while elevators and escalators comply with ASME A17.1. Generally, most commercial kitchens, elevators, and offices have this shunt trip breaker because it is required. You may also need a new line to connect the remote emergency switch to your breaker box. You may need to change the breaker panel and circuit breakers, especially if it is not compatible with shunt trips. Furthermore, you can use it as a manual emergency switch to shut down your main breaker.īefore installing a shunt trip, consider its cost and your existing system. This is especially true if you’re working with industrial machinery. However, it is recommended for added safety. Since this is an optional accessory for a circuit breaker, it is not required for a home electrical system. The shunt trip definition means that it is a way to cut off electrical power through other sensors, not just via thermal activation. It is crucial to know the difference between a regular circuit breaker and a circuit breaker installed with shunt trip accessories. It can also be installed with a remote switch, allowing you to trip your breaker manually. When activated, the shunt trip accessory will cause the main breaker to trip.įor example, if you install a shunt trip with a smoke detector, it will activate and cut off the power should the smoke sensor trigger. The control system can be connected to a sensor or to a manual switch. One connected to the ground, and another to a control system. Meanwhile, the shunt trip breaker wiring comprises two wires. It has no other purpose but to cut power in case of a short. It cannot be connected to any control package because the GFCI circuit breaker is solely designed to detect a sudden electrical surge. The GFCI circuit breaker contains one big white tail wire for neutral connections only. You should know that shunt trip breakers are different from GFCI circuit breakers. What is Shunt Trip Breaker and How Does It Work

  • How to Install a Shunt Trip Accessory to the Breaker.
  • Where Are Shunt Trip Breakers Most Used.
  • What is Shunt Trip Breaker and How Does It Work.